日本横河YOKOGAWA功率计CW500配件:98078、96060(2A)、96061(50A)、96062(100A)、96063(200A)、96064(500A)、96065(1000A)、96066(3000A)电流探头/CW500-B1-H
96066(3000A)电流探头
AP240E应用软件;探头:98078、96060(2A)、96061(50A)、96062(100A)、96063(200A)、96064(500A)、96065(1000A)、96066(3000A)
日本横河YOKOGAWA CW系列功率计:CW500、CW500-B0-H、CW500-B1-H、CW10、CW120、CW121、CW240
日本横河YOKOGAWA校验仪:CA150、CA310、CA320、CA330、CA700、CA71
94016交流适配器、90080 RJ传感器
CA700-E-01-U1-P1、CA700-E-01-U1-P2、CA700-E-01-U2-P1、CA700-E-01-U2-P2
CA700-E-02-U1-P1、CA700-E-02-U1-P2、CA700-E-02-U2-P1、CA700-E-02-U2-P2
CA700-E-03-U1-P1、CA700-E-03-U1-P2、CA700-E-03-U2-P1、CA700-E-03-U2-P2
CA700配件:
连接装置:91052、91057、91062
93052/93053
清洗装置:91040、91041
压力手泵:91050、91051、91055、91056、91060、91061
横河万用表:TY530、TY520、TY720、TY710、CA450、73101、73201/R、73202/R、73203/R、73204/R、DM7560
能效问题已受到范围内的普遍重视,需要有合适的产品来监视每个工厂的能量要求。CW240和CW120功率监视器系列允许客户使用便携式记录装置来测量电压、电流、功率、Var、VA、PF、PA、频率、谐波和需量。1P2W到3P4W功率监视器提供当前电力状况的可视化报告,以防止发生重大能耗问题或电费超支。
CW10与其说是记录仪,不如说是一款测试仪,可以测量单相AC和DC功率、电压、电流、功率因数、频率、谐波。该产品是用电设备维护人员的得力助手,也适用于太阳能和风力发电等可再生能源的设备。
The Yokogawa CW 500 is a portable power meter that utilizes current clamp-on probes, navigation screens and quick start guides to enable user friendly power consumption and power quality measurements in the field that conform to IEC6100-4-30 Class S.
Power Measuring and Logging
User Support
Quick Start Guide Function:
Vector Display:
Power Quality Measuring
Measure Temporary Malfunctions of the Power Line
Measure Continuous Malfunction of the Power Line
Harmonics
Flicker
Unbalance rate
CW 500Viewer (Included PC software)
Types of data
Memory card and interface
Power Measuring
Power line and Input Channel: 3 CH Voltage, 4 CH for Current Clamp Probe.
1P2W (up to 4 systems), 1P3W (up to 2 systems), 3P3W 2current (up to 2 systems), 3P3W 3current, 3P4W
Power measuring item:
Instantaneous, average, maximum, and minimum values for each setting period:
Voltage/Current/Power (Active, Reactive, Apparent)/Power Factor/ Phase Angle/Frequency/Calculated Phase Shift Capacitance/DC voltage value 2 CH.
Integration Value
Energy (active, reactive, apparent), Demand (list or graph display of change in a specific period and as a whole)
Recording Interval Period
1/2/5/10/15/20/30 second, 1/2/5/10/15/20/30 minute, 1 hour/2 hours
Recording method
Manual, time, period
Estimated Recording Length with 2 GB SD card
Various Measuring Screens
List display, zoom display by 4 or 8 divisions, trend graph display, integration value display for energy, demand list display of value, demand graph display for change of period, demand graph display for whole recording
List Display
Items of measured values can be selected with the curser key.
Zoom DisplayZoom display can be selected by 4 or 8 divisions.
Trend GraphTrend graph of voltage/ current/power/power factor/frequency/ advanced phase condenser external DC voltage.
Energy DisplayList of active, apparent, reactive by consumption or generation.
Demand measuring
Demand is the average power value of a specific period (usually 30 minutes). The contract with the power supplier conditionally concerns the maximum average power value between a period for the consumption fee. This function supports how to maintain within the target consumption by monitoring the estimated demand value to the setting rate with the maximum demand value.
List of Demand Value
Graph display of change on specific periodGraph display of whole demand trendAnalysis and Reporting of recorded dataAnalysis and reporting is enabled by simply clicking on the desired data on the software screen.
Analysis can be viewed by trend graph, overage, maximum and minimum value of voltage current, power, and power factor. Report generating can be set daily by daytime, nighttime, working day, or off day. It can also be set on a monthly period based on daytime or nighttime, working day or off day. Additionally, energy data to quantify into crude oil barrels or CO2 can also be converted.
Trend analysis graph
Sample of reportPower Quality Function
Short period power line malfunctions such as voltage swells, dips, interruptions, transients, over or inrush currents, or long periods of harmonic distortion/flicker may damage or reset your devices.
The CW 500 helps to identify each of those short period malfunctions by recording occurrence time, occurrence finish time and waveforms. Additionally there is a digital output on occurrence.
Long period malfunctions can be analyzed by harmonics, flicker, waveform, or by checking on the unbalance rate calculation for a 3 phase measurement.
All data can be finalized into a report format with the included software. The CW 500 conforms to the IEC standard of 61000-4-30 Class S.
User Support FunctionUser Friendly
Quick start guide and automatic type of clamp recognition
The quick start guide will show on-start measuring and how to wire and set the range before measuring. The automatic clamp detection will insure the settings are correct.
Start of guidance
PUSH the “START/STOP” key.
Select “Quick start guide”.
Select recording item.
WiringSelect the wiring and the appropriate connection diagram will be displayed.
Connect accordingly.
Wiring check/self diag./self id.Wiring check, self-check and the type of clamp is automatically detected and the results displayed.
If NG is displayed, the detail can be confirmed by pressing the “ENTER” key.
Recording settingSet the recording interval time and the recording time or period.
Power (under 240 VAC) can be supplied by using the power supply adapter (sold separay).
Leakage current measuring
The external magnetic field effect is 0.002 A or less, at 400 A/.
Yokogawa’s proprietary technology has achieved a magnetic field impact amount of 30 ppm even in adjacent power lines (at 100 A).
Below is an example of how to measure a neutral line of 3 phase 4 line.
4 system load measuring
Maximum of 4 systems are capable for 1 phase 2 line wiring.
Maximum of 2 systems are capable for 1 phase 3 line or 3 phase 3 line wiring.
96066(3000A)电流探头、96066(3000A)电流探头